Ductwork and airflow

Why is my upstairs or one room always hotter than the rest of the house?

Short Answer

A hot upstairs or one room that never cools almost always has a fixable cause. The usual culprits are systems that weren't sized from a Manual J load calculation, too little return air, or an undersized supply line to that room. The fixes run from upsizing or adding a supply line to balancing airflow across the whole house with dampers.

Why is my upstairs always hot?

It is one of the most common complaints we hear from Dothan homeowners. Most two-story homes have one system upstairs and one downstairs, and both need to be sized correctly using a block load calculation, called a Manual J.

Airflow matters as much as the size of the unit. The return air has to be able to get back to the units. We can also add dampers on the branches or the trunk line to even out airflow through the house.

Why is one room hotter or colder than the rest?

When one room won't heat or cool well, we go up in the attic and look at the supply line feeding it. One of the most common problems is an undersized supply line.

How do you fix one room that won't cool?

  • Upsize the line. We add an upsized takeoff and run a line sized to the CFM, or airflow, the room calls for.
  • Add a second supply line, if your system has enough airflow to support it.
  • Balance the whole house. We do a block load calculation on each room, check the airflow it gets, and add dampers on the supplies or the trunk.

If the problem is a duct that has come loose, our guide to attic ductwork covers the signs.

For current prices, see our Online Pricing page.

Common questions

What is a Manual J load calculation?

It is a block load calculation we use to size a home's systems correctly, including the upstairs and downstairs systems in a two-story home. We also run it room by room when we balance airflow.

Will a bigger AC fix a hot upstairs?

Not always. Both the upstairs and downstairs systems still have to be sized correctly with a Manual J load calculation. Airflow to the space matters as much as the size of the unit, and an oversized system creates humidity problems of its own.

Can dampers balance airflow between rooms?

Yes. Dampers on individual supplies, branches, or the trunk line let us even out airflow through the house.

Can an undersized supply duct make a room uncomfortable?

Yes. It is one of the most common causes of a single room that won't heat or cool. We fix it by upsizing the line to the airflow the room needs or by adding a second supply line.

Watch the videos

  1. One Room Always Too Hot or Too Cold?

    Length 1:12

    Three fixes for one room that won't heat or cool: upsize an undersized supply line, add a second supply line, or balance the whole house with dampers.

  2. Why Your Upstairs Is Always Hot

    Length 0:50

    The usual fixes for a hot upstairs: upstairs and downstairs systems sized from a Manual J load calculation, enough return air, and dampers to even out airflow.

Want us to take a look?